E10General EEPROM FaultProblem with communication between EEPROM and the microprocessor.Clear code, exit mode and start dryer. If problem persists, replace electronic control.
EllChecksum ErrorProblem with communications or memory did not check, one has become corrupted.Clear code, exit mode and start dryer. If problem persists, replace electronic control.
E12Non fetal R/W errorProblem reading or writing to the memory or input/output.Clear code, exit mode and start dryer. If problem persists, replace electronic control.
E24Control NTC Short CircuitControl thermistor or its wir- ing is shorted.Remove wires from control thermistor. Measure resistance of thermistor. If reading is not 50 K (± 10%), replace thermistor. If reading is within 50 K (±10%), check wiring between thermistor and electronic control. If good, replace electronic control.
E25Control NTC Open CircuitControl thermistor or its wiring is open.Remove wires from control thermistor. Measure resistance of thermistor. If reading is not 50 K (± 10%), replace thermistor. If reading is within 50 K (±10%), check wiring between thermistor and electronic control. If good, replace electronic control.
E4AProgram Time out FaultThe drying time has exceeded program time for that cyde.Press PAUSE CANCEL and SELECT buttons for 6 seconds to exit test modes. Position cyde selector to NORMAL, temperature selector to HIGH HEAT and touch START. Check for anything that would extend dry times such as: no heat, restricted vent, blower fan blade broken or loose, dryer installed in closet with solid door, or bad connection in moisture sensor bar arcuit or dirty bars. If dryer operates normally but code returns, replace electronic control.
E5BHeater Fault (no heating)Temperature reading of control thermistor has not changed in a certain amount of time.Position cyde selector to NORMAL, temperature selector to HIGH HEAT and touch START. Measure voltage across terminals on relay RL2 (heater relay) on electronic control. If meter reads 240V on electric models and 120V on gas models, replace electronic control. If meter reads zero, remove power from dryer. Disconnect wire going to NO terminal on the relay RL2. Reconnect power and measure voltage drop between terminal COM on relay RL2 and neutral. If meter reads zero, wire between incoming line and relay RL2 is open. If meter reads 120V, check the rest of the heater circuit.
E68Key (button) Struck FaultOne of the keys (buttons) is stuck dosed (active).Enter function test mode and perform key (button) test to determine which button is at fault. Carefully free the key (button) and perform the test again. If button is free but the key struck code still exists, replace electronic control.
E8CToo many trips in a period of time.The safety (high limit) thermostat has tripped too many times within a certain period of program time.Check for blocked lint filter, blocked exhaust, air leaks around air duct, broken blower fan blades, worn or loose drum seals, dryer installed in closet with solid doors or door seal not correctly seated.
EAFWatch Dog ResetMicrocontroller has been reset by internal Watchdog timer.Clear code, exit mode and start dryer. If problem persists, replace electronic control.

Electrolux affinity dryer error codes

Error CodeDescription
E31Moisture Sensor: Oscillation Frequency to High
E41Door Open at Cycle Start
E42Door Sensing Failure
E43Door Open During Cycle Execution
E51Motor Relay Failure
E52Motor Fault- Motor Stopped or Not Starting
E54Motor Sensing Failure
E61Heater Relay Failure
E63Heater to Earth Ground Failure
E64Heater Open Circuit
E65Heater Thermostat Trip Count too High
E66High Limit Thermostat Circuit Open
E67Heater Sensing Failure
E68Thermal Limiter Open Circuit
E71NTC 1 Open Circuit
E72NTC 1 Short Circuit
E91No Communication Between Main Board and User Interface
E92Protocol incongruence between main board and User Interface

Electrolux EIED55HIW – 8.0 cu. Ft. Electric dryer error codes

Error CodeFaultPossible Fault ConditionsPossible Solutions
E31Contact Sensor frequency too highElectronic Control Board defective or foreign object interfering with contact sensorCheck Contact Sensor and wiring. If no problems are found with Contact Sensor, replace Electronic Control Board.
E32Contact Sensor frequency too lowElectronic Control Board defective or foreign object interfering with contact sensorCheck Contact Sensor and wiring. If no problems are found with Contact Sensor, replace Electronic Control Board.
E42Door Sensing failureElectronic Control Board defectiveReplace Electronic Control Board.
E51Motor Relay failureMotor Relay stuck open or closed; Wiring defectiveIf motor runs continuously with power applied check for short circuit across motor relay (RL2). or L1 applied to motor relay output (J3-1) with cycle stopped. If motor does not start when 'start" key is pressed, check for open circuit between L1 and motor relay connection (J3-2). If no wiring problems found, replace Electronic Control Board.
E52Motor Fault - motor stopped or not startinqMotor overheating: Laundry load too heavy: Low power supply: Motor, or Wirina defectiveRemove any load from dryer and check if drum turns freely by hand. Check L1 power supply voltage, motor wiring, and motor thermal protector (if motor thermal protector has tripped, it may take up to 30 minutes to reset).
E53Motor Centripetal Switch FailureMotor Centripetal Switch. Electronic Control Board Defective, or wiring defective.Check wiring. Check if Motor Centripetal Switches are stuck in open or closed positions. Replace motor. Replace Electronic Control Board.
E54Motor Sensing failureElectronic Control Board defectiveReplace Electronic Control Board and retest.
E61Heater Relay failureHeater relay stuck open or closed; Wiring defectiveCheck for short circuit across heater relay(s) (RL5. RL6. RL7) or L1 applied to heater relay output(s) (J5-2, J7-1, J7-3) with cycle stopped. Check for open circuit between L1 and heater relay connection(s) (J5-1, J5-3, J7-2). If no wiring problems are found, replace Electronic Control Board and retest.
E63Heater to Earth GroundHeating element or wiring defectiveCheck heater coils and connections for short circuits to the cabinet. Replace heater and/or wiring and retest.
E64Heater Open CircuitHeating element or wiring defectiveCheck heater coils and connections for open circuits. Replace heater and/or wiring and retest.
E65High Limit Thermostat trip count too highHigh vent restriction. High Limit Thermostat defective or Inlet Thermal Limiter tripped (Electric Model only)For Electric Model, check Inlet Thermal Limiter for continuity. If Thermal Limiter is open, check for evidence of high temperature event and any resulting damage. If no further damage is evident, replace Thermal Limiter. If no problems are found with the Thermal Limiter, check exhaust vent system for air blockages. If no problems with vent restrictions, check/replace High Limit Thermostat, and retest.
E66Thermal Limiter Open CircuitOutlet Thermal Limiter tripped Inlet Thermal Limiter tripped (Gas Model only) or wiring defectiveCheck Outlet Thermal Limiter for continuity. For Gas Model, also check Inlet Thermal Limiter for continuity. If Thermal Limiter is open, check for evidence of high temperature event and any resulting damage. If no further damaqe is evident, replace Thermal Limiter and retest.
E67Heaters Sensing FailureElectronic Control Board defectiveReplace Electronic Control Board and retest.
E71Outlet Control Thermistor open circuitOutlet Control Thermistor or wiring defectiveCheck resistance of Outlet Control Thermistor, and check wiring for open circuit. Resistance should be between 4.9K Ohm and 6.2K Ohm at room temperature (68-77° F or 20-25° C). Replace Outlet Control Thermistor and/or wiring and retest.
E72Outlet Control Thermistor short circuitOutlet Control Thermistor or wiring defectiveCheck resistance of Outlet Control Thermistor, and check wiring for short circuit across Thermistor connections. Resistance should be between 4.9K Ohm and 6.2K Ohm at room temperature (68-77° F or 20-25° C). Replace Outlet Control Thermistor and/or wiring and retest.
E73Inlet Control Thermistor open circuitInlet Control Thermistor or wiring defectiveCheck resistance of Inlet Control Thermistor, and check wiring for open circuit. Resistance should be between 47K Ohm and 66K Ohm at room temperature (68-77° F or 20-25° C). Replace Inlet Control Thermistor and/or wiring and retest.
E74Inlet Control Thermistor short circuitInlet Control Thermistor or wiring defectiveCheck resistance of Inlet Control Thermistor, and check wiring for short circuit across Thermistor connections. Resistance should be between 47K Ohm and 66K Ohm at room temperature (68-77° F or 20-25° C). Replace Inlet Control Thermistor and/or wiring and retest.
E91Communication ErrorWiring. Electronic Control BoardCheck connections between Electronic Control Board and Interface Board. If no wiring problems, replace Electronic Control Board or Interface Board.
E92Incompatible protocolElectronic Control Board incompatible with Interface BoardCheck if correct Interface Board console and Electronic Control Board are installed. Replace appropriate hardware.
E93Machine configuration checksum errorWrong configuration data loaded. Interface Board or Electronic Control Board or wiring defectiveCheck if correct Interface Board and console are installed. Replace Interface Board and/or console.
E94Cycle configuration checksum errorWrong configuration data loaded or Electronic Control Board defectiveReplace Electronic Control Board.
E97Program mismatchWrong configuration data loaded. Electronic Control Board defectiveReplace Electronic Control Board.
EA1Main Supply Frequency out of RangeLine frequency out of limits or Electronic Control Board faultyCheck frequency of line voltage.
EA2Voltage too highLine voltage too high or Electronic Control Board faultyCheck amplitude of line voltage.
EA3Voltage too lowLine voltage too low or Electronic Control Board faultyCheck amplitude of line voltage.
EA4Improper home wiringLine connections in home faulty, wiring or Electronic Control Board defectiveCheck wiring at terminal block for L1-N-L2 wired incorrectly.
EA5Main V Sensing failureElectronic Control Board defectiveReplace Electronic Control Board.
EF1Vent BlockedHigh vent restriction. Exhaust Control Thermistor. Inlet Control Thermistor, or Electronic Control Board defectiveCheck vent restrictions and resistance values of Exhaust Control Thermistor and Inlet Control Thermistor.
EF3Max Timeout TimerExhaust blocked; Exhaust Control Thermistor. Inlet Control Thermistor. Contact Sensor or Electronic Control Board defectiveCheck vent restriction. Contact Sensor, and resistance values of Exhaust Control Thermistor and Inlet Control Thermistor
EF8Key StuckConsole button or Interface Board defectiveCheck buttons for activation when pressed. Replace console or Interface Board as appropriate

Electrolux T4130 dryer error codes

Error codeDescription
E 01Option Not in use.
E 02Option Not in use.
E 03Inlet air - Sensor has short-circuited The thermistor element measuring the air inlet temperature to the drum, or the wiring to the sensor has shorted.
E 04Outlet air - Sensor has short-circuited The thermistor element measuring the air outlet temperature from the drum, or the wiring to the sensor has shorted.
E 05Fan motor Motor 1: The thermal protection switch in the motor, or its harness, is open.
E 06Drum motor - Motor 2: The thermal protection switch in the motor, or its harness, is open.
E 07Option Not in use.
E 08Inlet and Outlet air protection thermostats One of the proctection thermostats has opened due to overheating.
E 09Option Not in use.
E 10Setting Programming error / incorrect or missing parameter(s).
E 11Drying error Maximum allowable RMC time exceeded (non-coin operated models only).
E 12Drying error Maximum allowable Autostop time exceeded (non-coin operated models only).
E 13Drying error - Requested drying time is longer than maximum allowed.(dryer connected to a payment system).
E 14Gas error - A flame was not detected on gas heated dryers.
E 15Vacuum switch The vacuum switch/pressostat does not shut within 12 seconds after the dryer is started.
E 16Vacuum switch The vacuum switch/pressostat was already closed when an attempt to start the dryer was made.
E 17Inlet sensor disconnected The inlet thermistor or wiring to the thermistor is open.
E 18Outlet sensor disconnected The outlet thermistor or wiring to the thermistor is open.
E 19Option Not in use.
E 20CMIS out of operation The dryer is put out of order in the PC programme.
E 21CMIS com board poll error The PC does not poll the dryer within the time out.
E 22LM10 com board poll error The PC does not poll the dryer within the time out.
E 23Option Not in use.
E 24Condensate container The condensate container is full and the pump is not pumping.

Electrolux T4300S dryer error codes

CodeCause/Solution
Error code E05 or E06When the error code E05 or E06 is displayed,this can be due to the motor being too hot.
Stop the dryer and wait for 5 minutes. Start again and choose a program. If this does not help and the error code reappears a service technician must be contacted.
Error code E12When the error code is displayed this can be due to the user having overfilled the dryer with clothes that are too wet.
Remove some of the clothes, close the door, and press the start button. If this does not help and the error code reappears a service technician must be contacted.
Error code E14When resetting gas error the dryer must be in operation on a program with heat, and the heat indicator must be on.
The dryer must only be reset three times.
If the dryer, however, has to be reset more than three times it has to be put out of order and a service technician must be called.
Error code E15When the error code is displayed this can be due to the user having overfilled the dryer.
Remove some of the clothes, close the door, and press the start button. If this does not help and the error code reappears a service technician must be contacted.
Error code E16The error code is displayed if the user presses the start button while the air pressure switch is already activated.
Resetting by opening / closing the door and pressing start button.

Electrolux T5190 dryer error codes

Error codeTextCause/Action
12.12DRYING ERROR WITH RMC PROGRAMThe longest permitted RMC time has been exceeded. (Applies only to machines with RMC). The machine is overfilled or the garment is too wet.
12.11DRYING ERROR WITH AUTOSTOP PROGRAMThe longest permitted automatic stop time has been exceeded. (Applies only to machines with automatic stop). The machine is overfilled or the garment is too wet.
12.10O.H. DRUM MOTORThe motor is too hot. The machine will restart automatically when the temperature on the motor is OK (if the door has not been opened).