Want to know how to decipher the error code your Kenmore dryer is displaying? This information will not only help you understand what’s going on with the appliance, but will also make it possible to make repairs on your own.
The range of dryers sold by Sears under the Kenmore brand is very wide and includes electric, gas, and portable dryers. The appliances are made by several manufacturers, including the world’s largest ones. The brand is owned by KCD IP, LLC, a Sears Holdings subsidiary. Kenmore is based in Chicago, Illinois.
Codes/Description |
---|
“tS”, “to", “tE" - Clogged Lint Screen. Vent is restricted. Clean the screen or vent. If the problem continues call for service. |
“dO”, udE” - Door is not closed properly to run the dryer. Close the door and then restart. If the problem continues call for service. |
“dF” - Door is not closing properly. Call for service. |
“bE”, “bE2” - Button stuck for more than 75 secs. Make sure a button is NOT being pressed continuously. Try restarting the cycle. If the problem continues call for service. |
“od” - Invalid Dry time. Call for service. |
“hE" - Invalid heating Tomp when running the dryer. Call for service. |
“Et” - EEPROM is not communicating properly. Try restarting the cycle. If the problem continues call for service. |
“FE” - Invalid power source Frequency. Try restarting the cycle. If the problem continues call for service. |
“9E” - Communication error between SUB PBA and MAIN PBA. Call for service. |
DISPLAY | CHECKING PART | CAUSE | REMARK |
---|---|---|---|
tE4 | Thermistor of steam generator | Steam generator thermistor open or shorted. | • tE4 error is only displayed in the test mode. |
• Replace the steam generator. | |||
E1 | Steam generator | Steam generator temperature exceeds 116 deg for more than 3 seconds. Steam hose or nozzle is clogged. | • Check the hose and nozzle for clogging. |
E3 | Steam generator | Sensors do not detect that steam generator is full within 60 seconds. | • If water in the steam feeder is less than about 2/3 full, this error may be displayed. Fill the feeder and restart the cycle. |
E4 | Steam generator | • Steam generator temperature does not rise 4°C every 2 minutes or the temperature is less than 80°€ for 3 seconds after steam temperature has been reached. | • Steam generator element is not heating and generator may need to be replaced. |
E5 | Pump | When the AD value of the pump less than 10 in the test mode. | • E5 error is only displayed in the test mode. |
• Replace the steam feeder pump. |
DISPLAY | CHECKING PART | CAUSE | REMARK |
---|---|---|---|
tE1 | Thermistor of blower housing | Outlet thermistor open or shorted. | • tE1 error is displayed in the drying cycle or test mode. |
• Replace the steam generator. | |||
tE2 | Thermistor of blower housing | Outlet thermistor open or shorted. | • tE2 error is displayed in the drying cycle or test mode. |
• Replace the steam generator. | |||
tE4 | Thermistor of steam generator | Steam generator thermistor open or shorted. | • tE4 error is only displayed in the test mode. |
• Replace the steam generator. | |||
E5 | Water supply pump | When the pump valve is less than 10 in the test mode | • tE5 error is only displayed in the test mode. |
• Check the connection between harness wire and connector. | |||
• Replace the water supply pump. | |||
Add water | Steam generator | Sensors do not detect that steam generator is full within 60 seconds. | • If water in the steam feeder is not enough this error may be displayed. Fill the feeder and restart the cycle. |
PS | Wire Connection (Black-White-Red) | Wire Connection is wrong. Wire Connection is loose. | |
*PS: "Power Supply" |
DISPLAY | Checking Part | Cause | Remark |
---|---|---|---|
tE1 | Thermistor of blower housing | • Thermistor open or shorted | • tE1 error is displayed in the drying cycle or test mode. |
tE2 | • Replace the steam generator. | ||
dE | Door SW | • Door SW is abnormal. (Only TEST MODE) | • dE error is only displayed in the test mode. |
PS | Wire Connection (Black-White-Red) | • Wire Connection is wrong. Wire Connection is loose. | Guidance of the wire connection. For only electric dryer. |
tE4 | Thermistor of steam generator | • Steam generator thermistor open or shorted. | • tE4 error is only displayed in the test mode. |
• Replace the steam generator. | |||
Add Water | Steam generator | • Sensors do not detect that steam generator is full within 60 seconds. | If water in the steam feeder is not enough this error may be isplayed. Fill the feeder and restart the cycle. |
E5 | Water supply pump | • When the pump valve is less than 10 in the test mode | • E5 error is only displayed in the test mode. |
• Check the connection between harness wire and connector. | |||
• Replace the water supply pump. | |||
EE | EE PROM Error | • EE PROM operation is abnormal. | • EE error is only displayed in the test mode. |
Codes/Description |
---|
“dc" - Unbalanced load prevented your Washer from spinning. Redistribute the load, press the Start/Pause Button. |
“dL" - Door is unlocked when Washer is running. Press the Power button to turn off your Washer, then restart the cycle. If the code reappears, call for service. |
“dS" - Door is open when Washer is running. Close the door tightly and restart the cycle. If the code reappears, call for service. |
“FL” - Your Washer failed to lock the door. Close the door tightly and restart the cycle. If the code reappears, call for sen/ice. |
“Hr” - Water temperature control problem. (Heater Control problem) Call for service. |
“LE" - Your Washer has tried to fill but has not reached the proper water level. Call for service. |
“LO” - The door will not unlock. Make sure the door is firmly closed. Push the Power button to turn off your Washer, then turn it on again. If the code reappears, call for service. |
“3E" - Motor not running properly. Restart the cycle pressing the Start/Pause Button. If the code reappears, call for service. |
“nd" - Your washer is not draining. It can also mean that the unit senses a small clog while draining. Before calling for service, check the following. 1) Turn off the unit and turn it on again. 2) Select only the Spin Cycle. 3) Press the Start/Pause to drain the water. If it still does not drain, call for service. |
“nP - Your Washer has tried to fill but was unsuccessful. Turn the machine off. Make sure the Water faucets are open all the way. Turn the machine on to check for kinked hoses. Turn the machine off. Then turn the machine on again to check the inlet screens on the fill hoses. If all looks good, press the Power button to activate the machine. |
“nF1" - This occurs when high-temperature water is supplied during the Wool course because the Hot and Cold valves are incorrectly connected. |
“Sr” - Problem with control. Call for service. |
“OE” - A fault is detected in the water level sensor. Call for service. |
“E2” - Jammed Key. Call for service. |
“7E” - Ag+ Kit problem. Call for service. |
“AE" - Communication error between SUB PBA and MAIN PBA. Call for service. |
“SF1”, “SF2”, “SF3” - System Error. Call for service. |
“tE" - Temperature sensor problem. Restart the cycle. If the code reappears, call for service. |
“2E” - High/Low voltage detected. Restart the cycle. If the code reappears, call for service. |
DISPLAY | DESCRIPTION | EXPLANATION / RECOMMENDED PROCEDURE |
---|---|---|
PF | Power Failure | PF flashes to indicate that a power failure occurred while the dryer was running. Press START to continue the cycle, or press STOP to clear the display. |
AF | Restricted Airflow Condition | AF flashes if a restricted airflow condition exists. Check to make sure the lint screen is clean, the door seal is in place and the vent is not obstructed. |
F-01 | Primary Control Failure | F-01 flashes when there is a primary control failure. Replace the machine control electronics. |
F-02 | Keypad/ User Interface Failure | F-02 flashes when there is a stuck button or user interface mismatch. This fault code will ONLY appear when in the diagnostic test mode. |
F-22 | Exhaust Thermistor Open | F-22 flashes if the exhaust thermistor is open. |
F-23 | Exhaust Thermistor Shorted | F-23 flashes if the exhaust thermistor has shorted. |
F-24 | Inlet Thermistor Open | F-24 flashes if the inlet thermistor is open. This fault code will ONLY appear when in the diagnostic test mode. |
F-25 | Inlet Thermistor Shorted | F-25 flashes if the inlet thermistor is shorted. This fault code will ONLY appear when in the diagnostic test mode. |
F-26 | Motor Drive System Failure | F-26 flashes if there is a motor drive system failure. |
F-28 | Moisture Sensor Open | F-28 flashes if the moisture sensor strip is open. This fault code will ONLY appear when in the diagnostic test mode. |
F-29 | Moisture Sensor Shorted | F-29 flashes if the moisture sensor strip has shorted. This fault code will ONLY appear when in the diagnostic test mode. |
F-30 | Restricted Airflow Condition | F-30 flashes if a restricted airflow condition exists. This fault code will ONLY appear when in the diagnostic test mode. Check to make sure the lint screen is clean, the door seal is in place and the vent is not obstructed. |
F-40 | Communication Error | F-40 flashes if the communication between the machine control and motor control is lost. |
F-41 | Blower Motor Failure | F-41 flashes when there is a blower motor failure. |
F-42 | Undervoltage Failure | F-42 flashes if the motor control detects a voltage less than 90 VAC. |
F-43 | Undervoltage Warning | F-43 flashes if the motor control detects a low voltage condition. The dryer will continue to run at a set blower speed. |
F-44 | Motor Control Failure | F-44 flashes when there is a motor control electronics failure. |
F-45 | Motor Control Speed Sensor Error | F-45 flashes when there is a motor control electronics speed sensor failure. |
F-46 | Blower Motor Error | F-46 flashes if the motor control detects an over-current or an over-torque condition. |
Codes/Description |
---|
“PF” (power failure), check the following: Was the drying cycle interrupted by a power failure? Press and hold START to restart the dryer. |
“L2" Diagnostic Code (low or no line voltage condition): The drum will turn, but there may be a problem with your home power supply keeping the dryer’s heater from turning on. The dryer will continue to run when this diagnostic code is present. Press any key to clear the code from the display and return to the estimated time remaining. Try the following: Check to see if a household fuse has blown or circuit breaker has tripped. Electric dryers use two household fuses or breakers. Replace the fuse or reset the circuit breaker. Confirm the power cord is properly installed. Select a Timed Dry heated cycle, and restart the dryer. If the message persists, consult a qualified electrician. |
“AF" (low airflow condition): The dryer will continue to run when this diagnostic code is present. Press any key to clear the code from the display and return to the estimated time remaining. Try the following: Clean lint screen. Check to see if the vent run from the dryer to the wall is crushed or kinked. Confirm the vent run from the dryer to the wall is free of lint and debris. Confirm the exterior vent exhaust hood is free of lint and debris. Confirm your vent system falls withing the recommended run length and number of elbows for the type of vent you are using. Select a Timed Dry heated cycle, and restart the dryer. If the message persists, have your entire home venting run cleaned. |
“F” Variable (F1, F2, F20, etc.) service codes: Call for service. |
A leak error. To fix a leak, do the following: Locate damaged hoses and replace…
To fix the error, you can try the following steps: Make sure the hoses are…
When it comes to reliable home appliances, Bosch is a brand that quickly comes to…
The Bosch dishwasher, a renowned name in the realm of kitchen appliances, has earned its…
Understanding the complexities of modern appliances like the Samsung dishwasher can be a daunting task.…
Kitchen appliances such as dishwashers are vital tools that help make our lives easier. Among…