LG DLEX3885 Series dryer error codes

DISPLAYCHECKING PARTCAUSEREMARK
tE1Thermistor of blower housingOutlet thermistor open or shorted.• tE1 error is displayed in the drying cycle or test mode.
• Replace the steam generator.
tE2Thermistor of blower housingOutlet thermistor open or shorted.• tE2 error is displayed in the drying cycle or test mode.
• Replace the steam generator.
tE4Thermistor of steam generatorSteam generator thermistor open or shorted.• tE4 error is only displayed in the test mode.
• Replace the steam generator.
E5Water supply pumpWhen the pump valve is less than 10 in the test mode• tE5 error is only displayed in the test mode.
• Check the connection between harness wire and connector.
• Replace the water supply pump.
Add waterSteam generatorSensors do not detect that steam generator is full within 60 seconds.• If water in the steam feeder is not enough this error may be displayed. Fill the feeder and restart the cycle.

LG DLEX5101W dryer error codes

DISPLAYChecking PartCauseRemark
tE1Thermistor of blower housing• Thermistor open or shorted• tE1 error is displayed in the drying cycle or test mode.
tE2• Replace the steam generator.
dEDoor SW• Door SW is abnormal. (Only TEST MODE)• dE error is only displayed in the test mode.
PSWire Connection (Black-White-Red)Wire Connection is wrong. Wire Connection is loose.Guidance of the wire connection. For only electric dryer. PS: Power Supply
tE4Thermistor of steam generator• Steam generator thermistor open or shorted.• tE4 error is only displayed in the test mode.
• Replace the steam generator.
Add WaterSteam generator• Sensors do not detect that steam generator is full within 60 seconds.If water in the steam feeder is not enough this error may be isplayed. Fill the feeder and restart the cycle.
E5Water supply pump• When the pump valve is less than 10 in the test mode• E5 error is only displayed in the test mode.
• Check the connection between harness wire and connector.
• Replace the water supply pump.
EEEE PROM Error• EE PROM operation is abnormal.• EE error is only displayed in the test mode.

LG DLEY1201 dryer error codes

CodesCauseSolution
The display shows "d907'd95"• The duct work is about 90%-95% blocked. ("d90" or "d95" error code displayed 2 hours only)
• House exhaust system blocked.
• Do not use the dryer until the exhaust system has been cleaned and/or repaired. Using the dryer with a severely restricted exhaust is dangerous and could result in a fire or other property damage.
• Check the outside dryer vent while the dryer is operating to make sure there is strong airflow.
• If the exhaust system is extremely long, have it repaired or rerouted.
• Keep the area around the dryer clean and free of clutter.
• Check vent hood for damage or lint clogging.
• Make sure the area around the vent hood is clear.

LG GD1329CGS dryer error codes

PROBLEMPOSSIBLE CAUSESOLUTION
tE1It is displayed when thermistor is open.Thermistor should be replaced.
tE2It is displayed when thermistor is shorted.Thermistor should be replaced.
CAEDisconnection of card reader wire.Check the card reader wire.

LG RC9055PZ dryer error codes

DisplaySymptomCheck Dolnt
tE1Low temperature themistor open/short (Drum out)1) Connector — not assembled?- Open
Check weather connector in connected correct or not?
2) If the covering has been peeled away or touch? - Short If the penetration of water? - Short
Check if any damage in harness or not?
3) Thermistor element — dead
Check if thermistor resistance in normal or not?
4) Check the voltage from main PCB to thermistor High or low voltage? —* Replace Main PCB
* Thermistor Resistance : 10k£ ±5% at 25‘C
tE2High temperature themistor open/short (Comp out)1) Connector — not assembled?- Open
Check weather connector in connected correct or not?
2) If the covering has been peeled away or touch? - Short If the penetration of water? - Short
Check if any damage in harness or not?
3) Thermistor element — dead
Check if thermistor resistance in normal or not?
4) Check the voltage from main PCB to thermistor High or low voltage? —* Replace Main PCB
* Thermistor Resistance : 234~364k£ at 25'C
tE3Heater themistor open/short (Drum in)1) Connector — not assembled?- Open
Check weather connector in connected correct or not?
2) If the covering has been peeled away or touch? - Short If the penetration of water? - Short
Check if any damage in harness or not?
3) Thermistor element — dead
Check if thermistor resistance in normal or not?
4) Check the voltage from main PCB to thermistor High or low voltage? —* Replace Main PCB
* Thermistor Resistance : 15&~240ki? at 25’C
tE4Low temperature themistor open/short (Evaporator In)1) Connector -»not assembled?- Open
Check weather connector in connected correct or not?
2) If the covering has been peeled away or touch? - Short If the penetration of water? - Short
Check if any damage in harness or not?
3) Thermistor element —* dead
Check if thermistor resistance in normal or not?
4) Check the voltage from main PCB to thermistor High or low voltage? —» Replace Main PCB
* Thermistor Resistance : 10k Q ±5% at 25’C
CE1(DT(temperature) comp_out> 115’C ©Comp off and re-operation after 3minutes.1 .Check the environment temperature is high. (35 ‘C or more)
2. Check the cooling fan is working properly (in speed option) 1) Check the connection of connector.
3. Replace the Compressor.
dEThe door must be closed and start Button must be pressed for reoperation1 .Check the Door switch Connection.
2.Check the connection of connector (PCB).
3.Disassemble the Control panel asm.And check the door switch housing properly connected.
4.Replace the PCB
OEDrain pump error 0 check the drain pump properly work.1.Check the PCB Holder Connection.
2.Check the Pump connection of connector (Pump).
3.Disassemble the pump cover asm. And check the lint material.
4.Replace the PCB

LG TD-C7014 series dryer error codes

CodeCause/Solution
dE LED displays dE in case of the door open. The door must be closed and start Button must be pressed for re-operation.
EHE (ELE)Case 1. When black out or irregular current occurs.
- After removing ELB Connector, operate full time 1 Cycle.
Case 2. EHE (ELE) message expresses continuously because of aging items.
- Change the old items.
tEThe resistance of thermistor not normal Case 1. The Circuit of thermistor is troubled.
- Repair the Circuit of thermistor.
Case 2. Thermistor is troubled.
- Replace the Thermistor.
Case 3. The Controller is troubled.
- Repair or replace the Controller.

LG WM3677HW dryer error codes

ERRORSYMPTOMCAUSE
WATER INLET ERROR1E• Correct water level (246) is not reached within 8 minutes after water is supplied or it does not reach the preset water level within 25 minutes.
IMBALANCE ERRORUE• The load is too small.
• The appliance is tilted.
• Laundry is gathered to one side.
• Non distributable things are put into the drum.
DRAIN ERROROE• Not fully drained within 10 minutes.
OVER FLOW ERRORFE• Water is overflowing (water level frequency is over 213). # If FE is displayed, the drain pump will operate to drain the water automatically.
PRESSURE SENSOR ERRORPE• The SENSOR SWITCH ASSEMBLY is out of order.
DOOR OPEN ERRORdE• Door not all the way closed.
• Loose electrical connections at Door switch and PWB Assembly.
• The DOOR SWITCH ASSEMBLY is out of order.
HEATING ERRORtE• The THERMISTOR is out order.
OVER CURRENT ERRORCE• MAIN PWB ASSEMBLY is out of order.
• Winding in the STATOR ASSEMBLY is short-circuited.
LOCKED MOTOR ERRORLE•The connector (3-pin, male, white) in the MOTOR HARNESS is not connected to the connector (3-pin, female, white) of STATOR ASSEMBLY.
• The electric contact between the connectors (3-pin, male, white) in the MOTOR HARNESS and 4-pin, female, white connector in the MAIN PWB ASSEMBLY is bad or unstable.
•The MOTOR HARNESS between the STATOR ASSEMBLY and MAIN PWB ASSEMBLY is cut (open circuited).
• The hall sensor is out of order/defective.
BALL SENSOR ERRORbE• Loose Ball Sensor Connector.
• Ball Sensor is out of order.
* Displayed only when the START/PAUSE button is first pressed in the QC Test Mode.
EEPROM ERROREE• EEPROM is out of order.
* Displayed only when the START/PAUSE button is first pressed in the QC Test Mode.
POWER FAILUREPF• The washer experienced a power failure.
DRY HEATER ERRORdHE• The Dry Heater is out of order.
- Replace the Dry Heater
• The connector of the Dry Heater is not connected properly to the connector in the main PWB ASSEMBLY.
- Reconnect or repair the cannector.
• The Dry Fan Motor is out of order.
-Replace the fan motor.

Recent Posts

Speed Queen washer error code fl

A leak error.  To fix a leak, do the following: Locate damaged hoses and replace…

6 years ago

Speed Queen error code nf

To fix the error, you can try the following steps: Make sure the hoses are…

6 years ago

Bosch dishwasher e23 error

When it comes to reliable home appliances, Bosch is a brand that quickly comes to…

6 years ago

Bosch dishwasher e17 error

The Bosch dishwasher, a renowned name in the realm of kitchen appliances, has earned its…

6 years ago

Samsung dishwasher f3 error

Understanding the complexities of modern appliances like the Samsung dishwasher can be a daunting task.…

6 years ago

Samsung dishwasher error code f5

Kitchen appliances such as dishwashers are vital tools that help make our lives easier. Among…

6 years ago